Z:\DRAWINGS\ND000\ND80A-D-JAVA-MAN.dwg, 07/08/2002 09:09:13 AM, 1:8.12598
Note: To access the Water Dispense Valves, open door and remove Hoppers.
TO ADJUST HOT WATER FLOW RATE:
1. Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank.
2. Locate adjustment screw on Dispense Valve.
3. Using Allen Key or flat screwdriver rotate, 1/4 turn at a time,
CLOCKWISE to decrease water flow, or COUNTERCLOCKWISE to increase water flow.
4. Check water flow output, after each 1/4 turn.
P510A
C-CLIP
CD77A
SOCKET
MIXING CHAMBER ASSEMBLY K600Q
JAVA GIANT2/3
H333A S.S.
DISPENSING TUBE
K600A
EXTENSION TUBE
CD61A CLEAR
CD272 BLACK
STEAM CAP
K529A AERATOR
K644A
DISPENSE
NOZZLE
ASS'Y
CD242 CLEAR
CD273 BLACK
MIXING CUP
DISPENSE CUP ASSEMBLY
MODELS:
JAVA GIANT 2 (USA & Canada)
JAVA GIANT 3 (USA & Canada)
DISPENSE VALVE: HOT WATER FLOW RATE:
L561A 2 TO 4.5 oz. factory set at 3.8 oz./sec.
L561A 2 TO 4.5 oz. factory set at 3.8 oz./sec.